Lync Hammertoe Fixation System
Lync® Hammertoe Fixation System
Secure Fixation for Hammertoe Correction
Engineered for small bones, the Lync® Hammertoe Fixation System is a single-piece, bifocal design with barbed leg configuration to ensure secure fixation. The streamlined three-step procedure ensures efficient surgical execution, enhancing surgical outcomes and patient recovery.
Hammertoe Correction- Overview
- Related Products
- Documents
The Lync® Hammertoe Fixation System® delivers immediate, controlled compression designed to resist pullout and rotation.
- No freezing required—primed for immediate use.
- Dual fixation zones with controlled compression.
- Simple 'lock and load' for retrieval, insertion, and deployment.
M0 |
M10 |
S0 |
S10 |
DIP |
|
---|---|---|---|---|---|
Medium M0o/M10o | Small S0o/S10o | DIP | |||
References | M0o – CM010010 | M10o – CM010011 | S0o – CM010030 | S10o – CM010031 | CM010040 |
1. Total Length | 20 mm | 20 mm | 16 mm | 16 mm | 12 mm |
2. Proximal Length | 13 mm | 13 mm | 11 mm | 11 mm | 6 mm |
3. Distal Length | 7 mm | 7 mm | 5 mm | 5 mm | 6 mm |
4. Initial/Final Proximal Opening | 2/8.5 mm | 2/8.5 mm | 2/8 mm | 2/8 mm | 2/5 mm |
5. Initial/Final Distal Opening | 3.5/4.5 mm | 3.5/4.5 mm | 3.5/5.5 mm | 3.5/5.5 mm | 3.5/4 mm |
6. Offset* | 0o | 10º | 0o | 10º | 0o |
* Straight or with a 10° bend for precise anatomic fitting and alignment.
Precision Engineering
A single-piece implant, engineered from anodized titanium (ASTM F67 / ISO 5832-2), featuring insertion tapers and migration-resistant talons for precise placement and stable bone purchase. Medullary canal preparation and device insertion are streamlined by eliminating the need for guide wires.
Three-step Procedure
You simply Ream, Rasp and Reduce. The multi-purpose implantation Forceps boast a uniquely designed Lock and Load feature for seamless implant-to-instrument transfer, quick insertion, and manual one-click compression.
Minimal Instrumentation
All required instruments are neatly configured in one elegantly sized sterilization module. No Freezing
Refrigeration is not required and the LYNC® implants may be used at ambient temperature; there are no costly storage expenses or timing issues involved.
Two Zones of Fixation
Proximal and distal leg pairs are designed to impart bifocal compressive forces for enhanced stability and resistance to pullout.
Controlled Compression
The malleability and modulus of elasticity of LYNC®’s pure titanium design delivers immediate, controlled compression with stable bone purchase that resists pullout, rotation or toggle. When fully deployed with insertion forceps, the proximal and distal leg pairs naturally conform to the internal geometry of the medullary canal without cortical perforation.