Secure Fixation for Hammertoe Correction

Engineered for small bones, the Lync® Hammertoe Fixation System is a single-piece, bifocal design with barbed leg configuration to ensure secure fixation. The streamlined three-step procedure ensures efficient surgical execution, enhancing surgical outcomes and patient recovery.

Hammertoe Correction
  • Overview
  • Related Products
  • Documents

The Lync® Hammertoe Fixation System® delivers immediate, controlled compression designed to resist pullout and rotation.

  • No freezing required—primed for immediate use.
  • Dual fixation zones with controlled compression.
  • Simple 'lock and load' for retrieval, insertion, and deployment.
ream-rasp-reduce@2x-100.jpeg
 
M0
M10
S0
S10
DIP
  Medium M0o/M10o Small S0o/S10o DIP
References M0o – CM010010 M10o – CM010011 S0o – CM010030 S10o – CM010031 CM010040
1. Total Length 20 mm 20 mm 16 mm 16 mm 12 mm
2. Proximal Length 13 mm 13 mm 11 mm 11 mm 6 mm
3. Distal Length 7 mm 7 mm 5 mm 5 mm 6 mm
4. Initial/Final Proximal Opening 2/8.5 mm 2/8.5 mm 2/8 mm 2/8 mm 2/5 mm
5. Initial/Final Distal Opening 3.5/4.5 mm 3.5/4.5 mm 3.5/5.5 mm 3.5/5.5 mm 3.5/4 mm
6. Offset* 0o 10º 0o 10º 0o

* Straight or with a 10° bend for precise anatomic fitting and alignment.

Lync-Measure-e1560529211623.jpeg

Precision Engineering

A single-piece implant, engineered from anodized titanium (ASTM F67 / ISO 5832-2), featuring insertion tapers and migration-resistant talons for precise placement and stable bone purchase. Medullary canal preparation and device insertion are streamlined by eliminating the need for guide wires.

Three-step Procedure

You simply Ream, Rasp and Reduce. The multi-purpose implantation Forceps boast a uniquely designed Lock and Load feature for seamless implant-to-instrument transfer, quick insertion, and manual one-click compression.

lync-diagram-1-1.jpeg
lync-xray.jpeg

Minimal Instrumentation

All required instruments are neatly configured in one elegantly sized sterilization module. No Freezing

Refrigeration is not required and the LYNC® implants may be used at ambient temperature; there are no costly storage expenses or timing issues involved.

Two Zones of Fixation

Proximal and distal leg pairs are designed to impart bifocal compressive forces for enhanced stability and resistance to pullout.

Controlled Compression

The malleability and modulus of elasticity of LYNC®’s pure titanium design delivers immediate, controlled compression with stable bone purchase that resists pullout, rotation or toggle. When fully deployed with insertion forceps, the proximal and distal leg pairs naturally conform to the internal geometry of the medullary canal without cortical perforation.

lync-spread-compression-2-1.jpeg